CVE-2024-47407
mySCADA myPRO OS Command Injection
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
Description
A parameter within a command does not properly validate input within myPRO Manager which could be exploited by an unauthenticated remote attacker to inject arbitrary operating system commands.
Official description from the CVE record, published by icscert. Copyright © 1999-2026 The MITRE Corporation. See /security/cve/legal for the CVE license. View the record on cve.org
Key data
CVSS 4.0 Critical 10.0
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
Attack vector: Network
The vulnerable component can be reached over a network, possibly from the Internet.
Attack complexity: Low
No measurable action is needed to get around the system's built-in security controls. The attack is repeatable.
Attack requirements: None
The attack works without any special deployment or execution conditions.
Privileges required: None
No account or privileges are needed.
User interaction: None
No action from any user is needed.
Vulnerable system: confidentiality: High
Serious or total effect on the secrecy of data.
Vulnerable system: integrity: High
Serious or total effect on the trustworthiness of data.
Vulnerable system: availability: High
Serious or total effect on availability.
Subsequent systems: confidentiality: High
Serious or total effect on other systems' data secrecy.
Subsequent systems: integrity: High
Serious or total effect on other systems' data trustworthiness.
Subsequent systems: availability: High
Serious or total effect on other systems' availability.
| Metric | Value | What it means |
|---|---|---|
| Attack vector | Network | The vulnerable component can be reached over a network, possibly from the Internet. |
| Attack complexity | Low | No measurable action is needed to get around the system's built-in security controls. The attack is repeatable. |
| Attack requirements | None | The attack works without any special deployment or execution conditions. |
| Privileges required | None | No account or privileges are needed. |
| User interaction | None | No action from any user is needed. |
| Vulnerable system: confidentiality | High | Serious or total effect on the secrecy of data. |
| Vulnerable system: integrity | High | Serious or total effect on the trustworthiness of data. |
| Vulnerable system: availability | High | Serious or total effect on availability. |
| Subsequent systems: confidentiality | High | Serious or total effect on other systems' data secrecy. |
| Subsequent systems: integrity | High | Serious or total effect on other systems' data trustworthiness. |
| Subsequent systems: availability | High | Serious or total effect on other systems' availability. |
CVSS 3.1 Critical 10.0
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Attack vector: Network
The vulnerable component can be reached over a network, possibly from the Internet.
Attack complexity: Low
No special conditions are needed. The attack can be repeated at will.
Privileges required: None
No account or privileges are needed.
User interaction: None
No action from any user is needed.
Scope: Changed
The impact can reach other components beyond the vulnerable one.
Confidentiality impact: High
Serious or total effect on the secrecy of data.
Integrity impact: High
Serious or total effect on the trustworthiness of data.
Availability impact: High
Serious or total effect on availability.
| Metric | Value | What it means |
|---|---|---|
| Attack vector | Network | The vulnerable component can be reached over a network, possibly from the Internet. |
| Attack complexity | Low | No special conditions are needed. The attack can be repeated at will. |
| Privileges required | None | No account or privileges are needed. |
| User interaction | None | No action from any user is needed. |
| Scope | Changed | The impact can reach other components beyond the vulnerable one. |
| Confidentiality impact | High | Serious or total effect on the secrecy of data. |
| Integrity impact | High | Serious or total effect on the trustworthiness of data. |
| Availability impact | High | Serious or total effect on availability. |
CVSS is owned and managed by FIRST.Org, Inc. (FIRST) and is used by permission. Each CVSS score on this site is shown together with its vector string, as published in the CVE record by the source named next to it. Learn more at first.org/cvss.
EPSS
- Score
- 0.63766 (63.8% probability)
- Percentile
- 99.2%
- Scores of
- Nov 10, 2026
- Model
- v2026.06.15
CISA assessment as of Nov 25, 2024
- Automatable
- yes
- Technical impact
- total
Weakness (CWE)
- CWE-78Improper Neutralization of Special Elements used in an OS Command
Affected products
mySCADA myPRO Manager
- affected: before 1.3
mySCADA myPRO Runtime
- affected: before 9.2.1
References