--- title: "How to Set Up a Pacemaker Corosync Cluster on Ubuntu 24.04" description: "Set up a three-node Pacemaker and Corosync high availability cluster on Ubuntu 24.04 with pcs, IPMI fencing, a floating IP and Nginx, then test failover." category: "Advanced Topics" language: en source: https://cubepath.com/docs/advanced-topics/clustering-with-pacemaker-and-corosync updated: 2026-09-25 --- # How to Set Up a Pacemaker Corosync Cluster on Ubuntu 24.04 Pacemaker and Corosync are the standard open source stack for high availability on Linux. Corosync handles cluster membership and quorum: it knows which nodes are alive and whether enough of them agree. Pacemaker is the resource manager: it decides where services run and moves them when a node fails. In this tutorial you will build a three-node cluster on Ubuntu 24.04 with `pcs`, configure fencing, and run Nginx behind a floating IP that moves to a healthy node automatically. ## Prerequisites - Three servers running Ubuntu 24.04 LTS, called `node1`, `node2` and `node3` in this guide. Three nodes let the cluster keep quorum when one fails; two-node clusters work but need special handling. - A non-root user with `sudo` privileges on each node. - A private network shared by all nodes at layer 2. This guide uses `10.0.0.11`, `10.0.0.12` and `10.0.0.13`. - A free address in that subnet for the floating IP, here `10.0.0.100`. - A working fencing method. On bare metal servers this is usually the BMC (IPMI) of each node; this guide uses `fence_ipmilan`. > Important: the floating IP is moved with gratuitous ARP. This works on a private layer 2 network or VLAN you control. Many cloud networks filter addresses that were not assigned to a VM, in which case the floating IP will not be reachable after a failover. Check with your provider before relying on it. ## Step 1 - Preparing the nodes Run this step on all three nodes. Each node must resolve the others by name over the private network. Add them to `/etc/hosts`: ```bash sudo nano /etc/hosts ``` ```text 10.0.0.11 node1 10.0.0.12 node2 10.0.0.13 node3 ``` Make sure the hostname of each server matches its entry (`hostnamectl` shows it; `sudo hostnamectl set-hostname node1` changes it). Cluster logs and fencing decisions are much easier to follow when clocks agree. Ubuntu 24.04 synchronizes time with `systemd-timesyncd` by default; confirm the clock is synchronized: ```bash timedatectl ``` ```output System clock synchronized: yes NTP service: active ``` Open the cluster ports to the private network only. `pcsd` uses TCP 2224 and Corosync uses UDP 5405 by default: ```bash sudo ufw allow from 10.0.0.0/24 to any port 2224 proto tcp sudo ufw allow from 10.0.0.0/24 to any port 5405 proto udp ``` ## Step 2 - Installing Pacemaker, Corosync and pcs On all three nodes, install the cluster stack, the `pcs` management tool, the base resource agents (which include `IPaddr2`) and the base fence agents (which include `fence_ipmilan`): ```bash sudo apt update sudo apt install pacemaker corosync pcs resource-agents-base fence-agents-base ``` The `pcs` package creates the `hacluster` user that `pcsd` uses to authenticate nodes to each other. Give it the same strong password on every node: ```bash sudo passwd hacluster ``` Ubuntu's `pacemaker` package starts with a placeholder single-node configuration. Remove it so `pcs` can create the real cluster: ```bash sudo pcs cluster destroy ``` Make sure `pcsd` is running and enabled: ```bash sudo systemctl enable --now pcsd sudo systemctl status pcsd --no-pager ``` ```output ● pcsd.service - PCS GUI and remote configuration interface Loaded: loaded (/usr/lib/systemd/system/pcsd.service; enabled; preset: enabled) Active: active (running) ``` ## Step 3 - Creating the cluster Run the rest of the `pcs` commands on `node1` only; `pcs` pushes the configuration to the other nodes. Authenticate the nodes to each other. Enter the `hacluster` password when prompted: ```bash sudo pcs host auth node1 addr=10.0.0.11 node2 addr=10.0.0.12 node3 addr=10.0.0.13 -u hacluster ``` ```output node1: Authorized node2: Authorized node3: Authorized ``` Create the cluster, start it on all nodes and enable it at boot: ```bash sudo pcs cluster setup hacluster01 node1 addr=10.0.0.11 node2 addr=10.0.0.12 node3 addr=10.0.0.13 sudo pcs cluster start --all sudo pcs cluster enable --all ``` `pcs` writes `/etc/corosync/corosync.conf` on every node with the knet transport and the node addresses you gave. Verify membership and quorum: ```bash sudo pcs status ``` ```output Cluster name: hacluster01 Status of pacemakerd: 'Pacemaker is running' Cluster Summary: * Stack: corosync (Pacemaker is running) * Current DC: node1 (version 2.1.6-6fdc9deea29) - partition with quorum * 3 nodes configured * 0 resource instances configured Node List: * Online: [ node1 node2 node3 ] ``` You will also see a warning that no STONITH resources are defined. That is the next step. ```bash sudo corosync-quorumtool ``` ```output Votequorum information ---------------------- Expected votes: 3 Highest expected: 3 Total votes: 3 Quorum: 2 Flags: Quorate ``` ## Step 4 - Configuring fencing (STONITH) Fencing (STONITH, "shoot the other node in the head") is what makes a cluster safe. When a node stops responding, the cluster cannot know whether it crashed or is still running the service while cut off from the network. Before starting the service elsewhere, Pacemaker powers the lost node off through an out-of-band channel, so two nodes never run the same resource and never write to the same data at once. Create one fence device per node, pointing at that node's BMC. Replace the BMC addresses, user and password with your own: ```bash sudo pcs stonith create fence-node1 fence_ipmilan ip=10.0.1.11 username=your_bmc_user password=your_bmc_password lanplus=1 pcmk_host_list=node1 sudo pcs stonith create fence-node2 fence_ipmilan ip=10.0.1.12 username=your_bmc_user password=your_bmc_password lanplus=1 pcmk_host_list=node2 sudo pcs stonith create fence-node3 fence_ipmilan ip=10.0.1.13 username=your_bmc_user password=your_bmc_password lanplus=1 pcmk_host_list=node3 ``` Before trusting a fence device, check that each node can reach the BMCs and read the power status: ```bash sudo fence_ipmilan --ip=10.0.1.12 --username=your_bmc_user --password=your_bmc_password --lanplus --action=status ``` ```output Status: ON ``` Keep a node from fencing itself by preferring other nodes to run each device: ```bash sudo pcs constraint location fence-node1 avoids node1 sudo pcs constraint location fence-node2 avoids node2 sudo pcs constraint location fence-node3 avoids node3 ``` Make sure fencing is enabled (it is by default) and test it on a node that is not running anything important yet: ```bash sudo pcs property set stonith-enabled=true sudo pcs stonith fence node3 ``` `node3` should power cycle, come back, and rejoin the cluster. Check with `sudo pcs status`. > Warning: if you are building a test lab without any fencing hardware, you can run `sudo pcs property set stonith-enabled=false` to let resources start. Never do this in production: without fencing, a network split can leave two nodes running the same service or corrupting shared data. ## Step 5 - Adding a floating IP and Nginx Install Nginx on all three nodes and disable its systemd unit, because Pacemaker, not systemd, decides where it runs: ```bash sudo apt install nginx sudo systemctl disable --now nginx ``` So you can see which node answers, put the hostname in each node's default page: ```bash hostname | sudo tee /var/www/html/index.html ``` Back on `node1`, set a default resource stickiness. It makes resources stay on their current node after a failed node comes back, instead of moving again and causing a second interruption: ```bash sudo pcs resource defaults update resource-stickiness=100 ``` Create the floating IP with the `IPaddr2` agent and Nginx with the `systemd` class, both in one group. Resources in a group always run on the same node and start in order, so the IP comes up before Nginx: ```bash sudo pcs resource create web-vip ocf:heartbeat:IPaddr2 ip=10.0.0.100 cidr_netmask=24 op monitor interval=10s --group web sudo pcs resource create web-nginx systemd:nginx op monitor interval=15s --group web ``` Check where the group is running: ```bash sudo pcs status resources ``` ```output * Resource Group: web: * web-vip (ocf:heartbeat:IPaddr2): Started node1 * web-nginx (systemd:nginx): Started node1 ``` From any machine on the private network, request the floating IP: ```bash curl http://10.0.0.100 ``` ```output node1 ``` ## Step 6 - Testing failover Put the active node in standby. Pacemaker stops the resources there and starts them on another node: ```bash sudo pcs node standby node1 sudo pcs status resources ``` ```output * Resource Group: web: * web-vip (ocf:heartbeat:IPaddr2): Started node2 * web-nginx (systemd:nginx): Started node2 ``` `curl http://10.0.0.100` now returns `node2`. Bring `node1` back: ```bash sudo pcs node unstandby node1 ``` Thanks to the stickiness you set, the group stays on `node2`. Next, test a service failure. On the node running the group, stop Nginx behind Pacemaker's back: ```bash sudo systemctl stop nginx ``` Within the monitor interval Pacemaker detects the failure and restarts Nginx. The failure is recorded: ```bash sudo pcs resource failcount show web-nginx ``` By default a resource moves to another node only after it fails `INFINITY` times on a node, meaning it is restarted in place. To move it after three failures, set `migration-threshold`: ```bash sudo pcs resource meta web-nginx migration-threshold=3 ``` Finally, test a real node failure by powering off the active node (or pulling its network cable). The remaining two nodes keep quorum, fence the lost node and start the group on one of them. ## Troubleshooting **Resources show as `Stopped` and `pcs status` warns about STONITH.** Pacemaker refuses to start resources until fencing is configured. Complete Step 4. **A resource is stuck in a failed state.** Check the reason and clear the failure history once the cause is fixed: ```bash sudo pcs status --full sudo journalctl -u pacemaker --since "15 min ago" sudo pcs resource cleanup web-nginx ``` **Nodes do not see each other.** Check the Corosync link status on each node and make sure UDP 5405 is allowed between them: ```bash sudo corosync-cfgtool -s ``` The output lists each link and should report the other nodes as `connected`. **The cluster lost quorum.** With three nodes, the cluster stops resources when two nodes are unreachable, because it cannot rule out that they are running them. Bring the nodes back rather than forcing quorum; overriding quorum is exactly how split brain happens. **The floating IP moves but is not reachable.** The network is probably filtering the gratuitous ARP or the address itself. Verify with `ip -brief address` on the active node that the IP is assigned, then check the network configuration with your provider. ## Conclusion You now have a three-node Pacemaker and Corosync cluster with fencing, a floating IP and Nginx that fails over when a node or the service fails. The same pattern applies to other services: add them as resources to a group, or use constraints for more complex layouts. As next steps, put HAProxy instead of Nginx behind the floating IP to load balance a pool of backends, add a shared or replicated storage resource such as DRBD for stateful services, and set up alerts on cluster events with Pacemaker's alert agents.